FOLLOW US:
Follow us:
CRI 70, CRI 90 and CRI 97 colour rendering comparison showing how light quality affects the appearance of fabrics and materials.

Lighting knowledge · For architects & interior designers

A beautiful light fixture is only part of the picture. The quality of the light it produces determines how we experience marble, timber, brass, textiles and artwork.

Two warm-white lamps can share the same colour temperature and still make an interior look remarkably different. One may preserve the subtle warmth of oak and the depth of red upholstery; the other may make those same finishes feel flat. To distinguish them, designers need more than a Kelvin number—or even a single CRI score.

This guide answers the questions that matter when specifying lighting for carefully considered interiors.

01 / The foundationsColour fidelity

What does CRI mean in lighting?

CRI (Colour Rendering Index), usually reported as Ra, indicates how closely a light source renders a standard set of colours compared with a reference illuminant of similar correlated colour temperature. The conventional Ra score averages eight test colours; 100 represents a match to the reference for those samples.

For many interior projects, CRI 90+ is a sensible starting point when colour appearance matters. But CRI alone cannot tell you exactly how a light source will render every fabric, stone or artwork. Two lamps with the same CRI may behave differently with saturated colours.

Is CRI 90 good enough for a design-led interior?

Sometimes, yes. A high-quality CRI 90 source may be entirely appropriate, particularly when its performance is supported by other measurements and evaluated in the actual space. For material-sensitive schemes, however, designers may choose CRI 95+ and inspect the additional colour-rendering data.

Rather than treating the highest CRI as an automatic guarantee, ask for the R9 value and, when available, an IES TM-30 report. The aim is to understand the whole spectrum, not to select one headline number.

Why does R9 matter?

R9 evaluates the rendering of a saturated red test colour. It does not contribute to the familiar average CRI Ra score. That is why a lamp can have a respectable CRI yet perform poorly with rich reds, some timber tones or warm-coloured materials.

R9 is particularly useful when evaluating light for interiors with warm woods, skin tones, textiles and artwork. A designer might specify R9 80+ as a demanding project target, but that is a design choice rather than a universal requirement. It should be considered alongside the light source’s other characteristics.

02 / Beyond the headline numberUnderstanding TM-30

What is IES TM-30, and how is it different from CRI?

IES TM-30 is a more detailed method of assessing colour rendition. Its current technical memorandum is ANSI/IES TM-30-24. Whereas the familiar CRI Ra calculation uses eight colour samples, TM-30 examines 99 colour evaluation samples and describes both colour fidelity and changes in colour saturation.

Metric What it tells you
CRI Ra Average colour fidelity across eight test samples
R9 Fidelity of a saturated red test colour
TM-30 Rf Average fidelity across 99 samples, relative to a reference
TM-30 Rg Overall colour gamut: whether colours are, on average, more or less saturated

TM-30 also includes a colour vector graphic that reveals which colour families shift and in which direction. This matters because average scores can conceal differences between individual hues. CRI Ra and TM-30 Rf use different methods and should not be treated as interchangeable numbers.

How should designers read Rf and Rg?

Rf measures fidelity to the reference: a higher value indicates closer average similarity. Rg describes average colour gamut relative to that reference. Rg of 100 indicates a similar overall gamut; above 100 generally means more saturation, while below 100 generally means less.

Neither a higher Rg nor an Rg of exactly 100 is always preferable. An art-focused project may prioritise faithful rendition; a hospitality interior may deliberately seek slightly richer visual colour. Designers should examine Rf, Rg, red rendering and the colour vector graphic together, in the context of the intended atmosphere.

03 / Light in the interiorTemperature and materials

2700K or 3000K: which is right?

Not inherently. 2700K describes a warmer white appearance, often chosen for living rooms, bedrooms and intimate hospitality spaces. 3000K is slightly less warm and can be useful where designers want a more neutral impression of finishes. Both may have excellent—or poor—colour rendition.

Kelvin describes the appearance of the light; CRI and TM-30 describe how it renders colours. A 2700K lamp with low red fidelity is not automatically a better choice for warm brass or timber than a well-specified 3000K source. Compare samples on site, under the intended illuminance and surrounding finishes.

How does light change the appearance of finishes?

Light interacts with each material’s surface and colour. Under one source, warm marble veining and brass patina may appear nuanced and layered; under another, those distinctions can become muted. Textured linen, dark timber and richly dyed upholstery deserve the same attention.

The effect is not just about colour metrics. Beam direction, glare, diffusion, brightness, contrast and surrounding daylight all influence how a material is perceived. A good lighting specification balances spectral quality with placement and optical control.

04 / From specification to selectionChoosing the light source

Integrated LED or replaceable bulb?

It depends on the construction. With an integrated LED luminaire, the installed LED system determines the source’s colour-rendering characteristics. With a replaceable-lamp luminaire, much depends on the exact lamp that the designer or installer selects.

Illuminated Lenox Wall Lamp in antique brass and a linen-cotton shade
Lenox Wall Lamp — an integrated-LED example from the Mapswonders lighting collection.

The Lenox Wall Lamp is specified with a 2700K integrated LED source, with published source specifications of CRI >98, R9 >95 and TM-30 Rf 95 / Rg 100. These figures describe the specified LED source; a project-specific technical confirmation remains advisable.

By contrast, the Renzo Wall Lamp uses a replaceable G9 bulb. The marble and brass fixture can shape the distribution and appearance of light, but its CRI, R9 and TM-30 performance depend on the chosen G9 lamp. A well-designed fixture and a well-specified bulb work together.

Which high-CRI LED lamps are worth comparing?

For luminaires with replaceable lamps, professional designers can consult the technical ranges below as independent specification references. They are examples of manufacturers publishing information about colour rendering, beam control or dimming—not a ranking, a universal endorsement or a guarantee of compatibility with a particular fixture.

  • Philips MASTER LEDspot ExpertColor GU10 — a directional GU10 example for European mains voltage. The linked 2700K, 25° model publishes CRI 97; check the precise model code for beam angle, dimmer compatibility and additional colour metrics.
  • SORAA VIVID — a useful range to investigate for colour-critical display and accent lighting, with carefully controlled beams. Compare the available GU10 models and their region-specific electrical ratings and technical reports.
  • Tala G9 LED bulb — an option to examine when a replaceable G9 capsule is required, including for a suitable project configuration of the Renzo Wall Lamp. Check the selected temperature, actual lamp dimensions, colour-rendering data and dimmer compatibility.
  • Zico Lighting GU10 — a professional range with warm-white, narrow-beam and dim-to-warm options. Zico also offers other lamp formats: choose by socket, required beam and control system rather than brand alone.
  • Waveform Lighting CENTRIC HOME — a high-colour-fidelity A19 reference with published CRI 95+ and R9 80+ figures. Check the precise base, electrical version and physical dimensions, particularly across North American and European projects.

Specification note: A lamp’s published CRI, R9 and TM-30 results apply to the relevant lamp or source, not automatically to a finished luminaire. A good match still requires verification of socket type (GU10, G9, E12/E14 or E26/E27), voltage, dimensions, thermal conditions, light distribution and dimmer compatibility. For a fully integrated LED luminaire such as Lenox, the manufacturer’s installed LED system—not a GU10 or G9 replacement bulb—remains the relevant reference.

05 / Practical specificationA designer’s checklist

What should you ask a lighting supplier?

Before approving a fixture or light source, request information that relates to the actual product configuration, not just a generic LED catalogue:

  • Colour rendition: CRI Ra and R9; TM-30 Rf, Rg and colour vector graphic where available.
  • Colour appearance: CCT (for example 2700K or 3000K), chromaticity consistency and tolerances.
  • Visual comfort: beam angle, glare control, diffuser details and the intended light distribution.
  • Dimming and performance: compatible driver/dimmer, flicker performance and behaviour at reduced output.
  • Project suitability: replaceability, serviceability, voltage compatibility and supporting technical documentation.

For colour-critical environments, request a working sample or a mock-up. Measurements help narrow the field; judging real materials in the completed setting remains an essential part of design.

06 / Our perspectiveLight as a design material

At Mapswonders, a luminaire is considered both as an object and as a source of illumination. The shape, finish and craft of a piece matter, but so does the quality of the light around it. That is why technical specifications should accompany the design conversation, especially when a project involves distinctive materials and carefully composed colour.

From the Mapswonders collection

Explore the Mapswonders lighting collection or our Trade programme to discuss project requirements, lighting specifications and suitable configurations.


Standards update: what CIE PS 002:2025 changes

The International Commission on Illumination (CIE) position statement PS 002:2025 recommends beginning the transition from the traditional CIE General Colour Rendering Index (Ra) towards the CIE General Colour Fidelity Index (Rf), which was defined in CIE 224:2017. During the transition, the CIE recommends that both metrics be reported. This matters for project specifications that still request CRI alone: the science and recognised reporting practices continue to evolve. The CIE also notes that colour fidelity is not the same as colour preference, and that additional methods are needed to characterise perceived preference.

Do not confuse CIE Rf with an entire TM-30 report

ANSI/IES TM-30-24 is a complete system for evaluating the colour rendition of light sources. Its report goes beyond a global fidelity score: alongside the average fidelity index Rf, it reports the gamut index Rg and local colour shifts, with a graphical breakdown across 16 hue-angle bins based on 99 colour evaluation samples. The CIE fidelity index has its own normative definition; specifications should identify which standard and edition were used rather than relying on an unexplained value labelled “Rf”.

What the numbers cannot decide for you

An Rg of 100 indicates approximately the same total gamut area as the reference; it does not mean that every colour is reproduced exactly, nor does a higher Rg automatically provide a better result. Colour-vector graphics and local chroma and hue-shift measures help show where the differences arise. The IES explains that average colour fidelity alone cannot describe the entire visual experience. For marble, oak, brass, upholstery or artworks, ask for reports for the specific source and configuration and evaluate physical samples under the intended beam, illuminance and dimming conditions.

Standards and technical reading: CIE PS 002:2025 — Position Statement on Colour Quality Metrics; ANSI/IES TM-30-24 (2024); Illuminating Engineering Society — Position on evaluating light-source colour rendition.

Further technical reading

For deeper technical guidance, consult the U.S. Department of Energy’s TM-30 questions and the Illuminating Engineering Society’s ANSI/IES TM-30-24 standard. The targets discussed above are illustrative design choices, not mandatory requirements for every project.